GasAlertMicroClip XT
Technical Reference Guide
36
Sensor Alarm
The detector tests for missing or defective sensors during the startup
self-test and continuously thereafter.
During start-up if a sensor fails, Error and the sensor name dis-
plays.
If a sensor fails the self-test, Err displays above the gas type of the
failed sensor. The detector will enter alarm. Press C to acknowl-
edge the sensor alarm and stoop the alarm. Refer to Troubleshoot-
ing.
Low Battery Alarm
Battery power is continually displayed during normal operation. If
battery power is low, L and flashes. The detector per-
forms a sequence of 10 rapid sirens and alternating flashes with
7 seconds of silence in between (continues for 15 minutes).
If battery power becomes critically low, L and
LOW BAT dis-
play. The detector performs a sequence of 10 rapid sirens with 1
second of silence in between (sequence reactivates seven times).
The detector then displays
OFF and the detector deactivates.
Charge the battery immediately. Refer to Charging the Battery
.
Note
Confidence Beep automatically disables during a low battery
alarm.
Automatic Deactivation Alarm
An automatic deactivation alarm will occur if
the battery voltage is too low to operate the detector,
calibration is due but not performed (when the Force Calibration
option is enabled),
bump test is due but not performed (when the Force Bump
options is enabled) and
all sensors fail during the startup self-test.
The detector performs a sequence of 10 rapid sirens with alternating
flashes with 1 second of silence in between (sequence reactivates
seven times). OFF then displays and the detector deactivates.