GasAlertMicroClip
Specifications
23
Year of manufacture: The detector's year of manufacture is
determined from the serial number. The second and third
number after the first letter determines the year of manufacture.
E.g., KA410-001000 = 2010 year of manufacture
Approved batteries:
Approved batteries for GasAlertMicroClip XT:
Narada NL 503759
Approved batteries for GasAlertMicroClip XL:
Narada NLP883759LT20
Rechargeable battery Temperature code
Lithium polymer -20°C Ta +50°C T4
Battery charger: GasAlertMicroClip charging adapter
a
Warning
Charge only in a safe area that is free of hazardous gas
and within temperatures of 0°C to 45°C (32°F to 113°F).
First-time charge:
XT: 2-3 hours
XL: 5-6 hours
Normal charge:
XT: 2-3 hours
XL: 5-6 hours
Warranty: 2 years including sensors
Approvals:
Approved by CSA to both U.S. and Canadian Standards
CAN/CSA C22.2 No. 157 and C22.2 152
ANSI/UL - 913 and ANSI/ISA - 12.13.01 Part 1
CSA Class I, Division 1, Group A, B, C, and D
ATEX CE 0539 g II 1 G Ex ia IIC T4 Ga
Sira 13ATEX2330
EN 60079-0, EN 60079-11, and EN 60079-26
IECEx Ex ia IIC T4 Ga IECEx CSA 05.0015
IEC 60079-0, IEC 60079-11, IEC 60079-26
KTL GasAlertMicroClip XT: 12-KB4BO-0053
GasAlertMicroClip XL: 14-KB4BO-0659X