GasAlertMicroClip XT
Operator’s Manual
10
Alarms
Refer to the following table for information about alarms and corresponding screens. If Stealth mode is enabled, the audible and
visual alarms are disabled. Only the vibrator alarm activates.
Alarm Display Alarm Display
Low Alarm
Slow siren
Slow alternating flash
L and gas bar flash
Vibrator alarm activates
TWA Alarm
Slow siren
Slow alternating flash
L and gas bar flash
Vibrator alarm activates
High Alarm
•Fast siren
Fast alternating flash
L and gas bar flash
Vibrator alarm activates
STEL Alarm
•Fast siren
Fast alternating flash
L and gas bar flash
Vibrator alarm activates
Multi-Gas Alarm
Alternating low and high alarm siren
and flash
L and gas bars flash
Vibrator alarm activates
Over Limit (OL) Alarm
Fast siren and alternating flash
L and gas bar flash
Vibrator alarm activates
OL displays